3. Experiment Execution
a. The hard drive from the “damaged” server, TSVR02,
was removed after it had been tested and determined that its
student accounts were accessible from the thin client.
b. All drives were removed from TSVR03 before
inserting the hard drive from TSVR02.
c. The hard drive was placed in the top hard drive
slot of TSVR03.
d. Upon the first attempt to reboot the server, there
was an immediate “Boot Configuration Error” showing on the
screen.
1) It was determined that the RAID array on TSVR03
had not been reconfigured for this experiment.
2) The hard drives in TSVR03 had been used under a
specific RAID array and when the “new” hard drive was
inserted, it was trying to read the hard drives in the order
for which it had been configured. When it could not find
the other drives, it provided the error.
e. The computer was rebooted and RAID was disabled in
the setup menu.
f. After RAID was disabled, the computer was
restarted and it was operational.
g. TSVR03 demonstrated connectivity with the network.
h. The Microsoft Management Control (MMC) “disk
management” showed that the swapped hard drive was healthy.
i. A log-on attempt from a thin client to TSVR03 was
attempted.